University of Limerick
Browse

Modified fiber optic sensor for highly precise identification of mercuric ion (Hg2+) concentrations in aqueous solution

Download (864.06 kB)
journal contribution
posted on 2021-05-13, 14:52 authored by Hummad Habib Qazi, Mohd Rashidi bin Salim, Abu Sahmah Bin Mohd Supa'at, Iftikhar Ahmed, Misbah Sehar Abbasi, Muhammad Mahmood Ali, Sevia Mahdaliza Idrus, Abu Bakar bin Mohammad, Muhammad Sultan Irshad, Farhat Yasmeen
A fiber optic sensor for monitoring mercuric (Hg2+) ions in the aqueous sample have been developed based on modified cladding. To fabricate a D-shaped sensing zone onto the multimode optical fiber lengthwise polishing was utilized using a mechanical end and edge polishing system. The produced sensing region has dimensions of 10 mm × 125 μm × 62 μm (l × w × h). A 2 μm thin layer of Al2O3 nanoparticles sensitized with 4-(2-pyridylazo)-resorcinol was deposited onto the sensing element of multimode fiber optic sensor to make it sensitive and selective for Hg2+ ions. The analytical results demonstrate that the sensing device has a linear response for Hg2+ ions concentration over a range from 4 to 16 ppm along with a 4 ppm limit of detection in an aqueous sample at room temperature. The selectivity of the sensor is examined for the recognition of Hg2+ ions in presence of other cations such as zinc and/or lead ions up to 16 ppm in an aqueous solution. The main merits of this fabricated sensor are easy and safe installation, rapid response, enhanced linear response range, and better selectivity towards Hg2+ ions.

Funding

The cranial morphology of the Leptodactylid Anuran, Lymnodynestes dorsalis (Gray)

National Research Foundation

Find out more...

History

Publication

Engineering Research Express;3 (2)

Publisher

IOP Publishing

Note

peer-reviewed The full text of this article will not be available in ULIR until the embargo expires on the 01/04/2022

Other Funding information

Research Management Center (RMC)

Rights

This is the Accepted Manuscript version of an article accepted for publication in Engineering Research Express. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/2631-8695/abea29

Language

English

Usage metrics

    University of Limerick

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC