Loading...
NiO-TiO2 thick-films for detection of alcohol vapours at room temperature
Date
2004
Abstract
The response of screen-printed thick-films of NiO/TiO2 to organic solvent vapours was studied. It was found that these films displayed a significant resistance change in response to the vapours even at room temperature. The sensors displayed an inherent selectivity, proving most sensitive to toluene and propanol vapour; with comparatively low responses exhibited towards ethanol and methanol vapours. Very fast response and recovery times of 9s and 16s respectively were recorded for the devices upon exposure to 4,000ppm step changes in propanol concentration.
Supervisor
Description
peer-reviewed
Publisher
IEEE Computer Society
Citation
Proceedings of IEEE Sensors 2004;
Collections
Funding code
Funding Information
Enterprise Ireland (EI)
Sustainable Development Goals
External Link
Type
Meetings and Proceedings
Rights
https://creativecommons.org/licenses/by-nc-sa/1.0/