University of Limerick
Browse
Conroy_2018_Thermal.pdf (21.78 MB)

Thermal and mechanical analysis of a sodium-cooled solar receiver operating under a novel heliostat aiming point strategy

Download (21.78 MB)
journal contribution
posted on 2020-10-15, 13:52 authored by Timothy J. Conroy, Maurice N. Collins, James Fisher, RONAN GRIMESRONAN GRIMES
The nature in which a solar receiver in a concentrated solar power plant interacts with an accompanying heliostat field plays a significant role in plant performance and economics. An appropriate heat flux distribution should help deliver maximum receiver thermal performance, while minimising mechanical damage – thereby maximising power production and reducing costs. The current work presents an investigation into the thermal performance and mechanical reliability of a sodium-cooled solar receiver operating under heat flux profiles generated by a novel heliostat aiming strategy. A modification of the HFLCAL model is used to generate heat flux profiles for individual heliostats in a representative plant, and simulated annealing optimisation techniques are used to produce a novel heliostat aiming strategy. The importance of giving consideration to receiver limitations under non-uniform thermal boundary conditions in the development of a heliostat aiming strategy is demonstrated in this study, with mathematical optical, thermal, and mechanical models used to complete the analysis. An investigation has been conducted for a point-in-time resulting in maximum thermal loading conditions, with theoretical modelling techniques used to calculate receiver tube temperatures for aiming strategy yielded heat flux profiles, thereby allowing for the determination of heat losses and mechanical reliability through creep-fatigue damage. Results show that the simulated annealing algorithm can significantly improve heat flux homogeneity on the receiver, potentially reducing peak heat flux to less than 10% that of a single aiming point strategy, given an appropriate spillage allowance and aiming point grid size. A satisfactory configuration of spillage allowance and aiming grid size exists so as to supply maximum power to the receiver, while uniformly distributing the incident heat flux in order to meet mechanical reliability requirements. Based on the receiver design and conditions simulated in the analysis, a grid constructed of more than 81 aiming points (receiver area coverage of 32.7% ), and an additional spillage allowance of 10% allows the receiver to deliver maximum power output while retaining mechanical durability through a 30 year plant life cycle.

Funding

Using the Cloud to Streamline the Development of Mobile Phone Apps

Innovate UK

Find out more...

History

Publication

Applied Energy;230, pp. 590-614

Publisher

Elsevier

Note

peer-reviewed

Other Funding information

IRC

Rights

This is the author’s version of a work that was accepted for publication in Applied Energy. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Applied Energy, 2018, 230, pp. 590-614, https://doi.org/10.1016/j.apenergy.2018.08.113

Language

English

Usage metrics

    University of Limerick

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC